#Prolink #UPS #OnlineUPS #SmallComputerNetwork #LAN #WorkStations #Servers #PRO902ES
Upgrade from PRO902WS
Professional II Series (1P/1P) Tower is specifically designed for operation in poor power areas. They provides high power density with long backup time in compact size. It’s ideal for ATMs, banking and other business critical applications.
PRO902-ES
• True double-conversion
• Microprocessor control optimizes reliability
• Input power factor correction
• Output power factor 0.9
• Wide input voltage (110 V – 300 V)
• Converter mode available
• ECO mode for energy saving (Only available for 3KVA model)
• Generator compatible
• Smart SNMP works well with either USB or RS-232 together
• Emergency power off function (EPO)(Optional)
• Optional isolation transformer available
UPS Type : Tower
Phase : Single phase with ground
Rating (VA) : 2000
Nominal Power (W) : 1600
Dimension (mm) : 397 x 145 x 220
Weight (kg) : 17
What’s in the box:
1 x PRO902ES 2KVA Online UPS,
1 x AC Power Cord (Input),
1 x User Manual,
1 x USB Cable,
1 x CD-ROM (Professional Remote Monitoring Software)
Prolink Professional II Series (1P/1P) is a single-phase UPS system using microprocessor controlled true online double conversion technology and it can be used to provide protection for critical loads especially on IT applications. High input power factor correction in the system improves efficiency and reduces overall losses.
Users can easily monitor and access to their UPS status from a comprehensive LCD display. Both Tower and Rack Types of UPS systems have USB and RS-232 communication ports as standard, with a built-in intelligent
slot for additional adapters, protocol converters, and relay contact cards. SNMP option is also available for power management via SNMP manager and web browser.
In addition, the Emergency Power Off (EPO) function is also available to protect the personnel and the equipment in case of fire outbreak or other types of emergency.
=======================================================
For PRO802-ES Master Series (1P/1P) – Tower UPS
GENERAL
PRO802-ES UPS Type: Tower
Phase: Single phase with ground
Rating (VA): 2000
Nominal Power (W): 1800
Standard Model
Dimension (mm): 421 x 190 x 318 (D x W x H)
Weight (kg): 25.8
INPUT
Connection Type: IEC 320-C14
Nominal Voltage: 200/208/220/230/240 VAC
Voltage Range: 110-300 VAC (Based on load at 50%)
:160-300 VAC (Based on load at 100%)
Frequency Range: 40 Hz ~ 70 Hz
Power Factor: ≧0.99
THDi :≦ 5% @100~130VAC or 205-245VAC
THDU < 1.6% @ input and full linear load condition with battery fully charged OUTPUT
Connection Type: 8 x IEC 320-C13
Nominal Voltage: 200/208/220/230/240 VAC
Voltage Regulation : ±1%
Frequency Range (Synchronized Range): 47~53 Hz or 57~63 Hz
Frequency Range (Batt. Mode): 50 Hz ± 0.1 Hz or 60Hz ± 0.1 Hz
Current Crest Ratio: 3:1
Harmonic Distortion: ≦2% THD (Linear load)
: ≦4% THD (Non-linear load)
ALARM & INDICATORS
Battery Mode: Sounding every 4 second
Low Battery: Sounding every second
Overload: Sounding twice every second
Fault: Continuously sounding
LCD: Load level, Battery Level, AC mode, Battery mode, Bypass mode and Fault
CONNECTIVITY, CONTROL & MONITORING
Front panel: Status LED, Function keys, LCD display
Communication: Smart RS232*
USB Port
Emergency Power Off (EPO)
BATTERY
Standard Model Type: 12V / 7Ah
Numbers: 6
Typical Recharge Time: 4 hours recover to 90% capacity
Long-run Model Type: Depending on the capacity of external batteries
Number: 6
Charging Current (max): 1A/2A/4A/6A/8A (Selectable via LCD setting)
REAR PANEL
1. Programmable outlets: connect to non-critical loads
2.Output receptacles: connect to mission-critical loads
3.AC input
4.Input circuit breaker
5.Network/Fax/Modem surge protection
6.Emergency power off function connector (EPO)
7.USB communication port
8.RS-232 communication port
9.Intelligent slot
10.External battery connection (Only available for L model)
11.Output terminal
12.Output circuit breaker
13.Cooling fan
Options | PRO802-ES, PRO902-ES |
---|